Home | About us | Editorial board | Search | Ahead of print | Current issue | Archives | Submit article | Instructions | Subscribe | Advertise | Contacts | Login 
  Users Online: 156 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size  
ORIGINAL ARTICLE
Year : 2017  |  Volume : 7  |  Issue : 1  |  Page : 23-27

Topical vasodilator response in skeletonized internal mammary artery: Is there really a difference?


1 Department of Medicine, Dow University of Health Sciences, Karachi, Pakistan
2 Department of Medicine, Ziauddin Medical University Hospital, Karachi, Pakistan
3 Department of Medicine, University of Illinois, Chicago, Illinois, USA

Correspondence Address:
Syed Raza Shah
Dow University of Health Sciences, Karachi
Pakistan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2231-0770.197510

Rights and Permissions

Aim of the Study: Coronary artery bypass graft surgery is the gold standard for the treatment of multivessel and left main coronary artery disease. However, there is considerable debate that whether left internal mammary artery (IMA) should be taken as pedicled or skeletonized. This study was conducted to assess the difference in blood flow after the application of topical vasodilator in skeletonized and pedicled IMA. Materials and Methods: In this study, each patient underwent either skeletonized (n = 25) or pedicled IMA harvesting (n = 25). The type of graft on each individual patient was decided randomly. Intraoperative variables such as conduit length and blood flow were measured by the surgeon himself. The length of the grafted IMA was carefully determined in vivo, with the proximal and distal ends attached, from the first rib to IMA divergence. The IMA flow was measured on two separate occasions, before and after application of topical vasodilator. Known cases of subclavian artery stenosis and previous sternal radiation were excluded from the study. Results: The blood flow before the application of topical vasodilator was similar in both the groups (P = 0.227). However, the flow was significantly less in pedicled than skeletonized IMA after application of vasodilator (P < 0.0001). Similarly, the length of skeletonized graft was significantly higher than the length of pedicled graft (P < 0.0001). Conclusion: Our study signifies that skeletonization of IMA results in increased graft length and blood flow after the application of topical vasodilator. However, we recommend that long-term clinical trials should be conducted to fully determine long-term patency rates of skeletonized IMA.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1101    
    Printed25    
    Emailed0    
    PDF Downloaded84    
    Comments [Add]    

Recommend this journal